Sample Inspection Report
Below is an interactive sample of our official diagnostic reports, detailing how snags are classified, documented, and given remediation instructions.
Inspection Findings Snippets
Moisture Intrusion & Dampness
Slab dampness saturation measured at 84% using an pinless moisture sensor. Visual inspection showed paint peeling, while thermal imaging confirmed cold moisture ingress from the balcony above due to faulty waterproof membranes.
Strip external tiles on the upper balcony, install high-density polyurethane waterproofing membrane, and repaint affected interior surface.
Electrical Breaker Overload
Infrared thermal scan of the main breaker panel showed circuit breaker #4 running at 82°C (hotspot). This indicates load overload on socket sockets, posing a moderate fire safety risk.
Balance household socket loads, check connection tightness at termination point, and replace the worn breaker switches.
Boundary Wall Settlement
A vertical hairline cracking (1.2mm width) was observed along the brick joints. No bowing or structural wall tilt detected. Crack is due to standard soft-soil settlement.
Monitor crack width over 6 months using tell-tale gauges. Patch with epoxy mortar sealant if stable.